Please contact SWAN certified technician for situations not mentioned below when the air compressor is out of order or malfunctions.
Fail to start:
- Check voltage and ensure the air compressor is connected to power supply correctly.
- Ensure the solenoid valve actuated normally and there’s no blocked and leakage.
- Check for any damage on the electrical wire, plug, and socket.
- Inspect the power switch, fuse, and control panel and fix or replace any damaged parts.
Overheated:
- Clean the fan and cooler regularly and ensure the airend is not blocked by any dusts.
- Maintain oil lubricant at sufficient level and genuine lubricant is recommended.
- Ensure well ventilation in the working environment and keep a minimum of 30cm clearance with the wall.
Leakage:
- Apply soapy water to the possible leakage area and check for any bubbles when the air compressor starts.
- Inspect the pipelines and connectors and tighten any loose parts. Apply sealant to increase strength.
- Check the gaskets and packings and replace any damaged parts.
Abnormal Noise:
- Inspect the bolts and nuts are tight securely.
- Check abnormal wear and tear on the air compressor interior parts such as piston, cylinder, and connecting rod.
- Inspect any loosen belt.
Excess Water:
- Check humidity of the environment. Inspect draining system and dryer function normally.
- Drain condensate water daily to prevent the air compressor from rusting and damaging.
- Install appropriate filters and dryers to eliminate the water vapor in the air.
Professional skills and knowledge are required for air compressor maintenance. Please contact experienced technicians for services. Regular maintenance and checkup prevent malfunction from happening.